REINFORCED CONCRETE STEEL FRAME COMBINATIONS

SEPARATING
WALLS
SEPARATING FLOORS
E-FC-2E-FC-10E-FS-1E-FS-2
E-WS-1 W 1 W W 1
E-WS-2 W W W
E-WS-3 W W W W
E-WS-4 W 1 W W 1

EFFECTIVE FROM MIDNIGHT ON 1 APRIL 2014

KEY
W Only the separating wall requires pre-completion sound testing.
1 Lightweight steel and timber frame walls may be constructed above in-situ poured concrete floors. The lightweight walls built directly off the concrete floors may be registerd as robust details™ provided:
  • they meet all other requirements of the robust detail™, including flanking constructions
  • the principles of the raft foundation junction are followed. As such, the concrete of the floor must have a mass of 365 kg/m2 (min), and a floating floor treatment must be provided.
Walls constructed to the soffit of in-situ poured concrete floors can not be registered as robust details™ and may be subject to pre-completion sound testing.

CODE FOR SUSTAINABLE HOMES
E-xx-nn 0-credit Robust Detail
E-xx-nn 1-credit Robust Detail
E-xx-nn 3-credit Robust Detail
E-xx-nn 4-credit Robust Detail
Invalid Combination
0-credit Combination
1-credit Combination
3-credit Combination
ECOHOMES
E-xx-nn 2-credit Robust Detail
E-xx-nn 3-credit Robust Detail
E-xx-nn 4-credit Robust Detail
E-xx-nn 4-credit Robust Detail
Invalid Combination
2-credit Combination
3-credit Combination
4-credit Combination